Tiles and whole boxes
Estimate tile pieces and whole boxes for a measured area. Choose a waste allowance for your own layout.
Estimate theoretical ARDEX FG1 grout use and whole 25 kg bags using its manufacturer formula.
Saved in this browser. Before changing devices, export a backup from My tools.
Only 5–10 mm joints are covered by this datasheet. Actual use depends on workmanship; trial first.
Only the ARDEX FG1 datasheet formula and coefficient 1.8 are used, for 5–10 mm joints and 25 kg bags. Do not treat this coefficient as a universal density for other products. Measure the dimensions and area, choose your waste allowance, trial actual coverage and verify the current datasheet. This does not assess suitability, waterproofing or safety.
This uses the ARDEX FG1 manufacturer formula and its 1.8 coefficient, for 5–10 mm joints and 25 kg bags only. It is not a universal density or formula for other products.
Measure dimensions and enter your own waste allowance. Actual use varies with conditions and workmanship; trial the work and check the current manufacturer datasheet. This does not assess waterproofing, safety or product suitability.
References:ARDEX FG1 datasheet: restrictions and theoretical coverage
Estimate theoretical material use and whole 25 kg bags for the specific ARDEX FG1 grout using the manufacturer formula.
Measure tile length and width, joint width and filled depth in millimetres; enter area in square metres and your own waste allowance.
Per square metre, multiply the sum of tile sides by joint width, filled depth and coefficient 1.8, then divide by tile area.
For a 300 by 300 mm tile with a 5 mm wide and 5 mm deep joint, the formula gives 0.3 kg per square metre.
Multiply theoretical use by area and your waste allowance; divide by 25 kg and round up to whole manufacturer bags.
The 1.8 coefficient and 5–10 mm width apply only to the FG1 datasheet. Site conditions vary; trial first and verify the latest documentation.
You are offline. Calculations use the version already downloaded.