Life Calculator
Understand the numbers · Make life easier

Room lighting and fixture count estimate

Estimate fixture count from area, target lux, labelled lumens and an assumed effective percentage.

Start with your own numbers

Editable example

An example is filled in. Replace it with your own data to calculate.

Enter area, your target average lux, lumens per fixture and assumed effective percentage.

Loading calculator…

Enter the area for this lighting zone.
Choose square metres or Taiwan ping.
Choose the desired average illuminance for your use.
Use the labelled light output per fixture, not wattage.
Enter your own assumed combined utilization and maintenance percentage.

Results update when inputs are complete. A plan is kept only when you save it. Inputs and results are not uploaded.

Saved plans →

Saved in this browser. Before changing devices, export a backup from My tools.

Example result

Estimated fixture count

10fixtures

This assumes uniform lighting; actual local brightness and safety are not guaranteed.

Estimated total fixture lumens8,000 lumens
Approximate average lux with whole fixtures200 lux
Converted area20 m²

Worked steps

  1. Area in square metres × target lux ÷ effective fraction = estimated total lumens
  2. Divide estimated lumens by lumens per fixture and round up.

Convert area to square metres. Required lumens = area × target lux ÷ effective fraction; divide by lumens per fixture and round up. The 50% effective fraction is an editable example, not a measurement, and combines utilization and maintenance losses. Fixtures, layouts, shades and wall colours vary. This uniform-average model cannot guarantee work-surface illuminance, uniformity, glare, safety or legal compliance. Verify with on-site measurements and professional guidance. Watts measure power, not brightness.

Method and scope

The effective fraction is an assumption, not a measured value.

A uniform average does not guarantee local brightness or compliance.

References:Taiwan MJIB: lighting and illuminance、US Department of Energy: lamp lumens

Purpose

Estimate how many matching fixtures a single indoor lighting area may need using your own lighting assumptions.

Inputs

Enter the measured area, your target average lux, labelled lumens per fixture and the assumed effective percentage.

Formula

Multiply the area in square metres by your target lux, divide by the effective fraction and lumens per fixture, then round up.

Example

For example, 20 square metres at 200 lux with 800 lm fixtures and 50% effectiveness gives 10 fixtures.

Reading the result

The whole fixture count is an approximation under the stated assumptions; local light distribution may differ.

Limits

This average uniform model cannot guarantee local illuminance, uniformity, glare, safety or legal compliance; measure on site.

Keep it handy for next time

Add Room lighting and fixture count estimate to your home screen

This icon opens this tool. Confirm installation in your browser.

  1. iPhone: Open in Safari, tap Share → Add to Home Screen, then confirm.
  2. Android: Open in Chrome and choose Install app or Add to Home screen from the menu.
  3. In an in-app browser such as LINE or Facebook, use its menu to open the page in Safari or Chrome first.

Browser options vary. A shortcut does not provide cross-device synchronization, and an installed app may have separate storage. Export a backup from My tools first. The first load requires a connection.

Checking offline data.