Baker percentages and dough weight
Build a dough formula from baker percentages or calculate percentages from ingredient weights. Flour is the 100% reference.
Estimate mixing-water temperature from measured conditions, or calculate a friction factor from a prior mix.
Saved in this browser. Before changing devices, export a backup from My tools.
The friction factor is not the actual rise; use measurements from the same equipment and recipe.
Without preferment, water = 3 × desired dough temperature − room − flour − friction factor. With preferment, multiply by 4 and subtract its temperature as well. Reverse the formula using measured dough and water temperatures to find the factor. The factor calibrates this approximation and is not the actual dough-temperature rise. Recheck with the same mixer, batch, time and speed; changed conditions require new measurements. Do not use extreme temperature results directly. This is not a food-safety or baking-success guarantee.
For straight dough, water = 3 × desired dough temperature − room − flour − friction factor. With preferment, use 4 × desired temperature and subtract the preferment temperature as well. Reverse the formula using measured final dough and water temperatures to find the factor.
The factor is a calibration term, not the actual dough-temperature rise. Recheck whenever the mixer, batch size, speed, time or recipe changes. Extreme estimated water temperatures are mathematical results, not instructions. Follow your recipe and equipment guidance; this does not guarantee food safety or baking results.
References:www.kingarthurbaking.com reference、www.kingarthurbaking.com reference
Estimate mixing-water temperature or calculate a friction factor from a measured trial mix.
Measure room and flour temperatures. Choose whether the recipe includes preferment. Enter a desired dough temperature and known factor, or a measured final dough temperature and the actual mixing-water temperature.
Use three temperature factors without preferment, or four with it. Multiply the target temperature, then subtract the measured inputs and friction factor.
Without preferment, 25°C target, 25°C room, 24°C flour and a friction factor of 6°C give 3 × 25 − 25 − 24 − 6 = 20°C water.
The number is a starting estimate. The friction factor is a formula term, not the actual rise in dough temperature.
If an estimate is below 0°C or above 40°C, do not use it directly. Adjust conditions and consult your recipe and equipment guidance. Real temperatures depend on batch size, ingredients and mixing.
You are offline. Calculations use the version already downloaded.